Skip to main content

System Alert - Overview

The system evaluates device and asset health and Inserts, Updates, or Closes alerts based on telemetry and activity. All alerts require the Smart Device or Asset to be assigned to an active (non-deleted) client.

Core Evaluation Criteria

  • Last Ping Cut-off: 36 hours
  • Image Data Cut-off: 72 hours
  • High Image Count Threshold: > 3 images in last 72 hours
  • Rejected Image Threshold: > 2 rejected images in last 72 hours
  • Alerts are Updated (Last Modified On) while conditions persist and Closed when conditions no longer apply.

System Alerts (summary table)

AlertTriggerIndicatesNotes / Thresholds
No CommunicationOEM or Retrofit asset at an active location has not pinged for >36 hoursPower loss, network issues, device malfunctionRequires active client assignment
Communication Without AssignmentDevice pinging within cut-off but has no linked Asset or is not assigned to an active LocationInstallation not mapped, missing assignment, incomplete uninstallValidate device→asset→location mapping
Modem Unplugged but Still WorkingRetrofit asset with MDM reports modem power OFF and missed pings (>36h)Modem/gateway unplugged, loose/faulty powerMDM-enabled devices only
Vista Insufficient BatteryDevice linked to asset/location reports battery below threshold with recent ping (within 36h)Battery near depletion, risk of shutdownBattery voltage threshold configured per device
High Image Count>3 images in last 72 hours + recent ping/image timestamps (within 36h) + installation >36hExcessive door activity, faulty/oversensitive sensor, camera instabilityImage cut-off = 72h
High Number of Rejected Images>2 rejected images in last 72 hours + recent ping/image timestamps + installation >36hPoor camera placement, low light, obstructed imagesRejection threshold = 2
No Image DataAsset is active and pinging but produces no valid images due to missing door-close events or incorrect door-handle locationCamera not capturing, door sensor misconfigurationCheck door event pipeline and handle config
No Door DataLast door-close event >36 hours or invalid door-handle location despite pingingDoor sensor malfunction, cooler not being usedDoor event cut-off = 36h
Communication from Inactive ClientPing received within 36 hours from a device assigned to an inactive clientDevice not properly decommissioned, incorrect client stateRequires client status validation
Inactive SKU DetectedImage processing identifies an inactive SKU in captured imagesNon-compliant SKUs present, planogram/retail execution issuesTriggered during image recognition workflows